Courses are offered at your facility (with your own
instrumentation) so you can learn using a system you are familiar with. All courses are
"hands-on" and teach practical instrument knowledge in a number of different
areas. Chiralizer is not affiliated with Agilent Technologies so you will receive
completely unbiased, expert information, hints and tips to allow you to instantly upgrade
your chromatography skills. Course prices are based on location, number of individuals and
topics covered. Custom courses designed to suit your exact needs can also be quoted.
Please email/phone us for more information. We are experts in chromatography so feel free
to discuss your needs with our scientists.
Some of our more popular HPLC and UHPLC courses
include :
HP / Agilent ChemStation Operation For HPLC
- An intermediate level overview of the software and
hardware features (includes review of the most popular Hardware modules (in either a 1050,
1090, 1100, 1200, 1260 or 1290 HPLC), detailed instrument set-up tips, method creation
& editing, sequences, report styles, simple automation, calibration tables, DAD
spectral features, peak purity, bandwidth, reference wavelengths, settings and common
maintenance procedures (PM's).
|
2
Days (CS-2001) |
HP / Agilent ChemStation Operation For HPLC (Advanced)
- Overview of special features including; Optimization
and operation of your HPLC and computer data system, automating calibration procedures,
automating methods, customization of standard reports, use of export file report feature
and use of diagnostic tests.
|
1 Day (CS-2002) |
HP / Agilent ChemStation Operation For HPLC (Mini-Course)
- A one day version of our CS-2001 course. An
introductory overview of the hardware features of either an HP 1050, 1090, 1100,
1200, 1260 or 1290 series HPLC system, method creation, method editing, naming,
sequence parameters, report styles, DAD spectral features (i.e. bandwidth,
reference, sample rate) and basic maintenance/service procedures under ChemStation
software.
|
1 Day (CS-2003) |
HP / Agilent LC-MSD Operation
- Overview of how to actually use HP’s newest
bench top LC-MS system to acquire accurate data. Includes hints and tips on the typical
set-up and operation with an electrospray source (ESI) to determine the correct molecular
weight of pharmaceutical compounds. Topics covered include; proper HPLC operation and
column selection for use in LC-MS, instrument calibration, choosing correct voltage ramps
and lens settings for different compounds, solvent choices, forming adducts, positive and
negative modes, use of post column doping, and interpretation of results.
|
1 or 2 Days (CS-2004) |
HP
1050/1090/1100/1200/1260/1290 Diode Array Optimization {HP ChemStation Topics}
- Use of the diode array detector in method
development. Includes an overview of ChemStation set-up and optimization for specific
applications and sample types. Advanced Peak Purity (The single most misunderstood
function), Use of reference wavelengths, proper flow cell, slit and wavelength selection
as well as library searching are covered. This is a 'hands-on" advanced level course for experienced users only.
|
1 Day (CS-2006) |
ChemStation
Quantification & Calibration {HP ChemStation Topics}
- Common procedure used to perform quantitative
analysis using the HP ChemStation software. Both the importance of proper method
development, operation, automation, when and how to update the calibration table data as
well as custom reporting topics are covered.
|
1 Day (CS-2008) |
Automated
HPLC Method Development {HP ChemStation Topics}
- Strategies to improve your method development
procedures using either the HP 1050, 1090, 1100, 1200, 1260 or 1290-Series HPLC
and/or LC-MSD system for "after hours" or unattended operation. Various
instrument add-ons as well as optimization of your existing hardware and software will be
discussed that can both improve your daily sample throughput as well as increase the
quality of your data.
|
1 Day (CS-2010) |
Chiral
HPLC Method Development Strategies
- Unbiased information (we do not sell columns
!) that will help you develop high quality chiral HPLC methods on your HPLC system.
Column, mobile phase selection and automation will be discussed. We are experts in the
chiral HPLC method development field.
|
1 Day (CS-2014) |
General
HPLC Method Development Strategies
- Unbiased information (we do not sell columns
!) that will help you develop high quality Reversed and Normal phase HPLC methods on your
HPLC system. Column, mobile phase selection and automation will be discussed.
|
1 Day (CS-2012)
|
HP 1050
Service and Maintenance
- Instructions and demonstrations as to how to repair
and maintain the HP 1050 HPLC modules. Includes all common maintenance procedures such as
piston, piston seal, needle, needle seat, rotor seal, flow cell cleaning, lamp testing and
replacement, custom diagnostic tests and troubleshooting procedures to keep your
instrument operating at it’s peak performance.
|
1 Day (CS-2050-3) |
HP 1090
Service and Maintenance
- Instructions
and demonstrations as to how to repair and maintain the research grade
HP 1090L or 1090M HPLC system. Includes all common maintenance
procedures such as piston, piston seal, needle, needle seat, rotor
seal, flow cell cleaning and repair, lamp testing and replacement,
optical switch replacement, wash system, rotary valve, metering pump,
HPIB configuration, installation of injector and/or pump upgrades,
custom diagnostic tests and troubleshooting procedures specific to DR-5
and PV-5 systems to keep your instrument operating at it’s peak
performance. This is a 'hands-on" advanced client level course for
experienced users only.
|
1 or 2 Days (CS-2090-3) |
HP /
Agilent 1100 & 1200, 1260 or 1290 Service and Maintenance
- Professional instruction and demonstrations at your
facility in how to repair and maintain one HP/Agilent HPLC system (e.g. 1100/1200,
1200/1260 or 1290-series HPLC System). Includes common maintenance procedures such as
piston, piston seal, needle, needle seat, rotor seal, flow cell cleaning and repair, lamp
testing and replacement, custom diagnostic tests plus troubleshooting procedures to keep
your instrument operating at it’s peak performance. This is a 'hands-on"
advanced client level course for experienced users only. CLASS COVERS ONE Instrument Version. SELECT ONE INSTRUMENT MODEL for class (e.g. 1100-series).
|
1 Day
Each Agilent 1100/1200-Series
(CS-2100-3);
Agilent 1200/1260-Series (CS-2260-3);
Agilent 1290-Series (CS-2290-3) |
Chiralizer™ Services,
L.L.C. USA
© Copyright 1993 to 2023, Chiralizer™
Services, L.L.C. All Rights Reserved.
E-mail : Sales@HPLCTOOLS.com
|